#. #this many watts is one FE/tick # Default: 34.0 # Range: 1.0E-4 ~ 1.7976931348623157E308 wattFeTConversionRate = 34.0 #. #[in kW] # Default: 100.0 # Range: 1.0 ~ 1.7976931348623157E308 converterMaxPower = 100.0 #. #[in Meters] # Default: 128 # Range: > 8 wireLength = 128 #. #[in Meters] # Default: 64 # Range: > 8 bundledWireLength = 64 #. #[in Meters] # Default: 32 # Range: > 8 heavilyInsulatedWireLength = 32 #. #[in Meters] # Default: 8 # Range: > 1 busWireLength = 8 #. #[in Meters] # Default: 64 # Range: > 8 catenaryLength = 64 #. # Default: 4 # Range: 1 ~ 8 wireItemsPerSpool = 4 #. # Default: 16 # Range: 1 ~ 32 wireViewDistance = 16 #. # Default: 500 # Range: > 100 maxFuseAmperage = 500 #. #Wires break when overloaded wiresBreak = false #. #Wires can cause damage to players and entities enableElectrocution = true #. #Uninsulated wires can connect enableCrossContact = false #. #Components get damaged when overloaded componentDamage = true #. #Doesn't return empty spools on wire placement alternateWirePlacement = false #. #Bulbs prevent mob spawns even when they are off bulbsPreventMobSpawns = true #. #Alternator Values [rotor] #. #. #SUs of 1 Watt # Default: 1.0 # Range: 9.999999747378752E-5 ~ 3.4028234663852886E38 rotorStressMultiplier = 1.0 #. #decide output power of alternators through voltage # Default: 48.0 # Range: 9.999999747378752E-5 ~ 3.4028234663852886E38 rotorPowerMultiplier = 48.0 #. #[in Amps] # Default: 100.0 # Range: 9.999999747378752E-5 ~ 3.4028234663852886E38 rotorFullLoadCurrent = 100.0 #. #Resistance Values [Resistances] #. #. #[in Ohms] # Default: 30.0 # Range: 0.1 ~ 1.7976931348623157E308 motorResistance = 30.0 #. #[in Ohms] # Default: 200.0 # Range: 0.1 ~ 1.7976931348623157E308 pumpResistance = 200.0 #. #[in Ohms] # Default: 1000.0 # Range: 0.1 ~ 1.7976931348623157E308 bulbResistance = 1000.0 #. #[in Ohms] # Default: 45.0 # Range: 0.1 ~ 1.7976931348623157E308 resistiveHeaterResistance = 45.0 #. #[in Ohms / Meter] # Default: 0.005 # Range: 1.0E-4 ~ 1.7976931348623157E308 wireResistance = 0.005 #. #[in Ohms / Meter] # Default: 0.005 # Range: 1.0E-4 ~ 1.7976931348623157E308 electrumWireResistance = 0.005 #. #[in Ohms / Meter] # Default: 0.01 # Range: 1.0E-4 ~ 1.7976931348623157E308 ironWireResistance = 0.01 #. #[in Ohms / Meter] # Default: 0.003 # Range: 1.0E-4 ~ 1.7976931348623157E308 ironRailResistance = 0.003 #. #[in Ohms] # Default: 1000.0 # Range: 1.0E-4 ~ 1.7976931348623157E308 indicatorBulbResistance = 1000.0 #. #[in Watts] # Default: 40000.0 # Range: 0.1 ~ 1.7976931348623157E308 electricTrainAccelerationPowerConsumption = 40000.0 #. #[in Watts] # Default: 20000.0 # Range: 0.1 ~ 1.7976931348623157E308 electricTrainCruisePowerConsumption = 20000.0 #. #Max ratings [Ratings] #. #. #[in Watts] # Default: 20000.0 # Range: 1.0 ~ 3.4028234663852886E38 variacMaxPower = 20000.0 #. #[in Watts] # Default: 1300.0 # Range: 1.0 ~ 3.4028234663852886E38 potentiometerMaxPower = 1300.0 #. #[in Watts] # Default: 1300.0 # Range: 1.0 ~ 3.4028234663852886E38 resistorMaxPower = 1300.0 #. #Voltage Values [Voltages] #. #[in Volts] # Default: 1900 # Range: > 0 trainMinVoltage = 1900 #. #[in Volts] # Default: 5000 # Range: > 0 trainMaxVoltage = 5000 #. #[in Volts] # Default: 1500.0 # Range: 0.0 ~ 1.7976931348623157E308 wireMaxVoltage = 1500.0 #. #[in Volts] # Default: 20000.0 # Range: 0.0 ~ 1.7976931348623157E308 heavilyInsulatedWireMaxVoltage = 20000.0 #. #[in Volts] # Default: 25000.0 # Range: 0.0 ~ 1.7976931348623157E308 highVoltageCapacitorVoltage = 25000.0 #. #[in Volts] # Default: 500.0 # Range: 0.0 ~ 1.7976931348623157E308 capacitorVoltage = 500.0 #. #[in Volts] # Default: 500.0 # Range: 0.0 ~ 1.7976931348623157E308 inductorVoltage = 500.0 #. #[in Volts] # Default: 10000.0 # Range: 0.0 ~ 1.7976931348623157E308 maxVoltmeterVoltage = 10000.0 #. #[in Amps] # Default: 200.0 # Range: 0.0 ~ 1.7976931348623157E308 maxAmmeterCurrent = 200.0 #. #[in Coulombs] # Default: 36000.0 # Range: 0.0 ~ 1.7976931348623157E308 maxAccumulatorCharge = 36000.0 #. #. #[in Volts] # Default: 80 # Range: > 0 motorMinVoltage = 80 #. #Train Values [trains] #. #. #[in Ticks / one Accumulator] # Default: 1200 # Range: > 1 trainAccumulatorTime = 1200 #. #[in Ticks / one Accumulator] # Default: 1200 # Range: > 1 trainAccumulatorChargeTime = 1200 #. #Sparks appear on electric trains in cold conditions. winterPantographSparks = true #. #Chance of a spark appearing in cold conditions. # Default: 0.009999999776482582 # Range: 0.0 ~ 1.0 winterPantographSparkChance = 0.009999999776482582 #. #Trains faster than this value will have sparks on pantographs. Set to 0 to disable. [in Blocks / Tick] # Default: 1.440000057220459 # Range: 0.0 ~ 3.4028234663852886E38 speedPantographSparkThreshold = 1.440000057220459 #. #Chance of a spark appearing at high speeds. # Default: 0.009999999776482582 # Range: 0.0 ~ 1.0 highSpeedPantographSparkChance = 0.009999999776482582 #. #Sparks appear on electric trains in rainy conditions. rainPantographSparks = true #. #Chance of a spark appearing in raniy conditions. # Default: 0.009999999776482582 # Range: 0.0 ~ 1.0 rainPantographSparkChance = 0.009999999776482582 #. #Simulation Configs [simulation] #. #. #Don't turn off unless you want to cook your TPS optimizeGraph = true #. #[EXPERIMENTAL] This describes how many times the simulation is run every tick. # Default: 1 # Range: 1 ~ 32 microTicks = 1